We use cookies to make your experience better.
To comply with the new e-Privacy directive, you agree to the privacy policy and our use of cookies.
Black Box LES431A serial server RS-232/422/485
SKU
LES431A
- Provides a gateway between Modbus® TCP and Modbus ASCII or RTU devices.
- Allows older PLCs and similar devices to talk to newer TCP sensors and meters.
- Enables you to monitor a serial industrial device from your office.
- Rugged design for operation in a wide temperature range.
- UL® Listed for use in Class 1 Division 2 hazardous areas.
- NEMA TS-2 rated for use in transportation applications.
- Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
- Offers Modbus messaging priority control, selectable by source or function code.
- Features a built-in Web server and easy-to-use management software.
- Can be easily integrated into most Modbus network configurations.
| SKU | LES431A |
|---|---|
| EAN | 0822088107163 |
| Manufacturer | Black Box |
| Availability | Out of Stock |
DETAILS
- UL Listed for use in Class 1 Division 2 hazardous areas.
- NEMA TS-2 rated for use in transportation applications.
- Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
- Offers Modbus messaging priority control, selectable by source or function code.
- Features a built-in Web server and easy-to-use management software.
- Can be easily integrated into most Modbus network configurations.
- Converts ASCII to RTU as well as ASCII or RTU to Modbus TCP.
- Features a DB9 port and terminal block for serial connections.
- Equipped with a 10-/100-Mbps port for TCP connectivity.
- Boasts high throughput with low latency.
- Slim IP30 enclosure saves you on DIN rail space.
- Includes a DIN mounting clip and spring.
Easily integrate an older serial Modbus device into your Ethernet Modbus network. This rugged serial server gives you a simple way to migrate to an Ethernet-based industrial control system—without having to replace the older Modbus equipment you've already invested in. Translating older and newer protocols, the 1-Port Modbus Hardened Serial Server converts mismatched serial baud rates and settings, enabling the serial Modbus device to become a node on your Ethernet network. Older PLCs can then talk to newer sensors, meters, scales, and other industrial monitoring and automation instruments. Configuration can be done through a direct serial connection or via the network, so you can improve productivity and cut down on the amount of time required to troubleshoot a serial device on a factory floor or in a remote location. Configure devices, upgrade firmware, and more—all this from the comfort of your office. A simple-to-install, user-friendly software application enables programming. No time-consuming setup is required. The software also features Modbus messaging priority control and allows management through multiple TCP/IP client sessions. The serial server can be configured for TCP client or server operation. A built-in traffic monitor provides instant verification of a successful installation, and you can view the serial server's operational status in real time. The 1-Port Modbus Hardened Serial Server has a standard DB9 serial port for RS-232 device connections and a removable terminal block for an RS-422 or RS-485 device connection. It also has an autodetecting 10BASE-T/100BASE-TX port for the Ethernet network connection. Either device on either side can be a Modbus master or slave, customizable to your application. A serial master can be configured to control an IP slave, for instance. Also, a serial slave device can be accessed over a LAN or WAN by up to 16 simultaneous Modbus TCP masters.
- UL Listed for use in Class 1 Division 2 hazardous areas.
- NEMA TS-2 rated for use in transportation applications.
- Routes Modbus traffic based on Modbus ID, and remaps conflicting Modbus IDs.
- Offers Modbus messaging priority control, selectable by source or function code.
- Features a built-in Web server and easy-to-use management software.
- Can be easily integrated into most Modbus network configurations.
- Converts ASCII to RTU as well as ASCII or RTU to Modbus TCP.
- Features a DB9 port and terminal block for serial connections.
- Equipped with a 10-/100-Mbps port for TCP connectivity.
- Boasts high throughput with low latency.
- Slim IP30 enclosure saves you on DIN rail space.
- Includes a DIN mounting clip and spring.
Easily integrate an older serial Modbus device into your Ethernet Modbus network. This rugged serial server gives you a simple way to migrate to an Ethernet-based industrial control system—without having to replace the older Modbus equipment you've already invested in. Translating older and newer protocols, the 1-Port Modbus Hardened Serial Server converts mismatched serial baud rates and settings, enabling the serial Modbus device to become a node on your Ethernet network. Older PLCs can then talk to newer sensors, meters, scales, and other industrial monitoring and automation instruments. Configuration can be done through a direct serial connection or via the network, so you can improve productivity and cut down on the amount of time required to troubleshoot a serial device on a factory floor or in a remote location. Configure devices, upgrade firmware, and more—all this from the comfort of your office. A simple-to-install, user-friendly software application enables programming. No time-consuming setup is required. The software also features Modbus messaging priority control and allows management through multiple TCP/IP client sessions. The serial server can be configured for TCP client or server operation. A built-in traffic monitor provides instant verification of a successful installation, and you can view the serial server's operational status in real time. The 1-Port Modbus Hardened Serial Server has a standard DB9 serial port for RS-232 device connections and a removable terminal block for an RS-422 or RS-485 device connection. It also has an autodetecting 10BASE-T/100BASE-TX port for the Ethernet network connection. Either device on either side can be a Modbus master or slave, customizable to your application. A serial master can be configured to control an IP slave, for instance. Also, a serial slave device can be accessed over a LAN or WAN by up to 16 simultaneous Modbus TCP masters.
| Technical details | |
|---|---|
| Stop bits | 1, 1.5, 2 |
| Data bits | 5, 6, 7, 8 |
| Auto MDI/MDI-X | Yes |
| Serial ports quantity | 1 |
| Serial interface type | RS-232/422/485 |
| RS-485 signals | Data+, Data-, GND |
| RS-422 signals | GND |
| RS-232 signals | CTS, DCD, DSR, DTR, GND, RTS, RXD, TXD |
| Networking standards | IEEE 802.3 |
| Flow control support | Yes |
| Data transfer rate | 0.234 Mbit/s |
| Certification | FCC Part 15, Class A, CE, NEMA TS2, UL Class 1, Division 2, Groups A, B, C, D |
| Baud rate | 230400 Kbit/s |
| Ports & interfaces | |
| Ethernet LAN (RJ-45) ports | 1 |
| Cabling technology | 10/100Base-T(X) |
| Weight & dimensions | |
| Weight | 100 g |
| Dimensions (WxDxH) | 81 x 119 x 30 mm |
| Power | |
| Power consumption | 4000 mA |
| Input voltage | 10 - 58 V |
| Operational conditions | |
| Storage temperature (T-T) | -40 - 85 °C |
| Operating temperature (T-T) | -40 - 80 °C |
| Operating relative humidity (H-H) | 10 - 95% |
| Protocols | |
|---|---|
| Supported network protocols | TCP, IPv4, UDP, ARP, HTTP 1.0, ICMP/PING, DHCP/BOOTP, DHCP,, TCP |
| Certificates | |
| Certification | FCC Part 15, Class A, CE, NEMA TS2, UL Class 1, Division 2, Groups A, B, C, D |
| Indication | |
| LED indicators | Yes |
| Software | |
| Windows operating systems supported | Windows 7, Windows Vista, Windows XP Home, Windows XP Home x64, Windows XP Professional, Windows XP Professional x64 |
| Server operating systems supported | Windows Server 2003, Windows Server 2008 |
| Design | |
| International Protection (IP) code | IP30 |
| Product colour | Black |
| Certification | FCC Part 15, Class A, CE, NEMA TS2, UL Class 1, Division 2, Groups A, B, C, D |