We use cookies to make your experience better.
To comply with the new e-Privacy directive, you agree to the privacy policy and our use of cookies.
APC SY200K250DR-PD uninterruptible power supply (UPS) 200 kVA 200000 W
SKU
SY200K250DR-PD
Login for pricing
Call for availability
Symmetra PX 200kW Scalable to 250kW with Right Mounted Maintenance Bypass and Distribution
Output power capacity | 200 kVA |
---|---|
Product colour | Black |
Output power | 200000 W |
SKU | SY200K250DR-PD |
EAN | 4250234561730 |
Manufacturer | APC |
Availability | Out of Stock |
InfraStruXure Central compatible
Enables centralized management via APC InfraStruXure® Central.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Modular design
Increases adaptability with an open architecture configurable to any IT environment.
Modular design
Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
SmartSlot
Customize UPS capabilities with management cards.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Audible alarms
Provides notification of changing utility power and UPS conditions.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Enables centralized management via APC InfraStruXure® Central.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Modular design
Increases adaptability with an open architecture configurable to any IT environment.
Modular design
Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.
Dual mains input
Increases availability by allowing the UPS to be connected to two separate power sources.
SmartSlot
Customize UPS capabilities with management cards.
Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Battery modules connected in parallel
Delivers higher availability through redundant batteries.
Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Audible alarms
Provides notification of changing utility power and UPS conditions.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Power | |
---|---|
Output power | 200000 W |
Emergency Power Off (EPO) | Yes |
Output power capacity | 200 kVA |
Battery | |
Battery type | VRLA |
Battery recharge time | 3.50 h |
Features | |
Output power | 200000 W |
Emergency Power Off (EPO) | Yes |
Output power capacity | 200 kVA |
Input frequency | 40/70 Hz |
Design | |
Product colour | Black |
Certification | cUL Listed,CE,EN/IEC 62040-2,EN/IEC 62040-3,EN/IEC 62040-1-1,UL 1778,UL 60950-1,UL Listed |
Operational conditions | |
---|---|
Operating temperature (T-T) | 0 - 40 °C |
Storage temperature (T-T) | -15 - 40 °C |
Operating relative humidity (H-H) | 0 - 95% |
Storage relative humidity (H-H) | 0 - 95% |
Operating altitude | 0 - 999.9 m |
Non-operating altitude | 0 - 15000 m |
Weight & dimensions | |
Weight | 4095.4 kg |
Certificates | |
Certification | cUL Listed,CE,EN/IEC 62040-2,EN/IEC 62040-3,EN/IEC 62040-1-1,UL 1778,UL 60950-1,UL Listed |
Other features | |
Battery type | VRLA |
Output connections | 1x Hard Wire 4-wire (3PH + G) 1x Hard Wire 5-wire (3PH + N + G) |
Input connection type | Hard Wire 4-wire (3PH + G), Hard Wire 5-wire (3PH + N + G) |
Dimensions (WxDxH) | 3100 x 1070 x 1991 mm |